Highlights
Provides a redundant power option for critical networking equipment with a single input power cord
2 digit display reports output power consumption in amps
1U horizontal rack-mount form factor; 14.8 in. / 37.6 cm depth
10 outlets (8 C13, 2 C19)
Set of Plug-lock output power cable retention sleeves prevent accidental disconnection of connected devices
Set of two C20 inlets support connection to separate PRIMARY and SECONDARY power sources
Two 12-ft. / 3.6m C19 to C20 power cables included
ATS circuits normally maintain output sourced from the primary input cable; As primary input power fails or becomes unstable, the ATS will switch to maintain output sourced from the secondary input cable until power on the primary input is restored and stable
ATS configurations enable fault-tolerant, hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system (in a two-UPS environment, the primary input cable must be supported by an online UPS with zero transfer time similar to SmartOnline series)
Advanced ATS configurations utilizing separate mains circuits, backup generators and even separate out of phase utility power grid feeds are fully supported
On-board ATS processor constantly evaluates power quality on both inputs to prevent transfer to the secondary source when unavailable or of lower quality than the primary source
Super-fast switchover between primary and secondary power sources occurs in 2-5 milliseconds
Built-in card slot supports optional SNMPWEBCARD or WEBCARDLX for permanent upgrade to a switched & monitored PDU system
Outlets are factory programmed for sequential turn-on at 250 millisecond intervals when the PDU is first energized to prevent inrush-related equipment interaction on startup
Front panel LEDs confirm power availability on both input lines
Federal Trade Agreements Act / TAA Compliant for GSA Schedule purchases
Good to know
Product Design
-
Housing material
Metal
-
Mounting
Horizontal
-
On/off switch
No
-
PDU types
Metered
-
Rack mounting
No
Ports & interfaces
-
AC outlet types
C13 coupler,C19 coupler
-
AC outlets quantity
10.000000
-
Power plug
C20 coupler
Features
-
Cable length
3.600000
-
Certification
UL 60950 (USA, Canada), CE (Europe), Class A (Emissions), NOM (Mexico)
-
Colour-coded outlets
No
-
Daisy chain
No
-
LED indicators
Y
Power
-
AC input frequency
50 - 60
-
Circuit breaker
No
-
Maximum current
20.000000
-
Nominal input voltage
200-240
-
Nominal output voltage
200-240