Skip to content

Tripp Lite PDUMH32HVATNET 7.7kW Single-Phase Switched Automatic Transfer Switch PDU, Two 200-240V IEC309 32A Blue Inputs, 16-C13 2-C19 Outlets, 2U, TAA

SKU
PDUMH32HVATNET
7 pieces available
In stock
Tripp Lite PDUMH32HVATNET 7.7kW Single-Phase Switched Automatic Transfer Switch PDU, Two 200-240V IEC309 32A Blue Inputs, 16-C13 2-C19 Outlets, 2U, TAA, Switched, 2U, Single-phase, Horizontal, Metal, Black

Sign in for pricing

  • Personalised pricing

  • Dedicated account team

  • Order by 3pm for next day delivery

  • CRN Senior Public Sector VAR Winner

Overview
Full specs

Overview

Highlights

The PDUMH32HVATNET 7.7kW Single-Phase 200-240V Switched Automatic Transfer Switch / ATS PDU provides remote power monitoring and enables redundant power for network devices with non-redundant power supply configurations. Ideal for data centers and server rooms, it mounts in 2U of space in EIA-standard racks and features 18 switched outlets (16 C13 and two C19) in two load banks, each bank protected by a 20A circuit breaker.

Dual 3-meter input cords with IEC309 32A Blue (2P+E) plugs connect to separate primary and secondary single-phase 230V power sources. The PDU constantly evaluates the power quality of both input sources. Dynamic solid-state (TRIAC) automatic transfer switching allows the PDU to switch to the secondary source within 1–5 milliseconds should the primary source fail or become unstable to ensure your connected equipment operates without interruption.

Built-in LX Platform network management interface. The Java-free LX Platform HTML5-based network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separate) provide a variety of environmental monitoring capabilities. Protocols supported include HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP.

Good to know

Product Design

  • Mounting
    Horizontal
  • Housing material
    Metal
  • PDU types
    Switched
  • Product type
    Single-phase

Ports & interfaces

  • Ethernet LAN (RJ-45) ports
    1
  • AC outlets quantity
    18
  • Power plug
    IEC309
  • AC outlet types
    C13 coupler, C19 coupler

Features

  • Cable length
    3
  • LED indicators
    Y

Power

  • Nominal output voltage
    200-240
  • Nominal input voltage
    200-240
  • Maximum current
    32
  • Maximum power
    7700
  • AC input frequency
    50 - 60

Full Specs

    Product Design
    • Mounting
      Horizontal
    • Housing material
      Metal
    • PDU types
      Switched
    • Product type
      Single-phase
    Ports & interfaces
    • Ethernet LAN (RJ-45) ports
      1
    • AC outlets quantity
      18
    • Power plug
      IEC309
    • AC outlet types
      C13 coupler, C19 coupler
    Features
    • Cable length
      3
    • LED indicators
      Y
    Power
    • Nominal output voltage
      200-240
    • Nominal input voltage
      200-240
    • Maximum current
      32
    • Maximum power
      7700
    • AC input frequency
      50 - 60
    Weight & dimensions
    • Dimensions (WxDxH)
      444 x 317 x 88
    Operational conditions
    • Storage temperature (T-T)
      -15 - 50
    • Operating relative humidity (H-H)
      5 - 95
    Packaging data
    • Package dimensions (WxDxH)
      424 x 505 x 198
    • Package weight
      9120
    • Package depth
      505
    • Package height
      198
    • Package width
      424
    Management features
    • Supported network protocols
      HTTP, HTTPS, PowerAlert®, SMTP, SNMPv1, SNMPv2, SNMPv3, Telnet, SSH, FTP, DHCP, BOOTP, NTP
    Packaging content
    • Manual
      Yes
    Logistics data
    • Country of origin
      Taiwan
    • Products per master (outer) case
      1
    Certificates
    • Compliance certificates
      RoHS
    Sustainability
    • Sustainability certificates
      RoHS

More Information

Specifications

  • Manual
    Yes
  • Product type
    Single-phase
  • Dimensions (WxDxH)
    444 x 317 x 88
  • Package dimensions (WxDxH)
    424 x 505 x 198
  • Operating relative humidity (H-H)
    5 - 95
  • Storage temperature (T-T)
    -15 - 50
  • Nominal output voltage
    200-240
  • Nominal input voltage
    200-240
  • Mounting
    Horizontal
  • Power plug
    IEC309
  • AC input frequency
    50 - 60
  • Supported network protocols
    HTTP, HTTPS, PowerAlert®, SMTP, SNMPv1, SNMPv2, SNMPv3, Telnet, SSH, FTP, DHCP, BOOTP, NTP
  • LED indicators
    Y
  • Country of origin
    Taiwan
  • Housing material
    Metal
  • AC outlet types
    C13 coupler, C19 coupler
  • PDU types
    Switched
  • Sustainability certificates
    RoHS
  • Compliance certificates
    RoHS
  • Package weight
    9120
  • Cable length
    3
  • Ethernet LAN (RJ-45) ports
    1
  • AC outlets quantity
    18
  • Maximum current
    32
  • Package depth
    505
  • Package height
    198
  • Package width
    424
  • Maximum power
    7700
  • Products per master (outer) case
    1

Reviews

Write Your Own Review
You're reviewing:Tripp Lite PDUMH32HVATNET 7.7kW Single-Phase Switched Automatic Transfer Switch PDU, Two 200-240V IEC309 32A Blue Inputs, 16-C13 2-C19 Outlets, 2U, TAA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.