Skip to content

Tripp Lite SU6000RT4UHVG SmartOnline 208/240, 230V 6kVA 5.4kW Double-Conversion UPS, 4U Rack/Tower, Extended Run, Network Card Options, USB, DB9 Serial, Bypass Switch, C19

SKU
SU6000RT4UHVG
Your price £2,151.18
Out of stock
SmartOnline 208/240, 230V 6kVA 5.4kW Double-Conversion UPS, 4U Rack/Tower, Extended Run, Network Card Options, USB, DB9 Serial, Bypass Switch, C19
View full product details
Sign in or register your company account to unlock exclusive benefits:
 
  • Shop top tech from leading brands
  • Order by 3pm for next day delivery
  • 24/7 account access
Overview

More Information

Highlights

Tripp Lite SU6000RT4UHVG 6000VA / 6kVA / 5400 watt on-line, double-conversion UPS system offers complete power protection for critical server, network and telecommunications equipment in a single 4U rack/tower compatible housing. Full-time active power conditioning provides clean, continuous dual-conversion AC output free of voltage fluctuations, power interruptions and line noise. Fault-tolerant auto-bypass prevents unexpected service interruptions during UPS overload or internal fault conditions. Detachable back panel PDU with manual bypass switch supports hot-swappable whole UPS replacement with no interruption to connected equipment. Single all-in-one rack / tower housing installs in only 4 rack spaces (4U) with a maximum installed depth of only 20.7 in. / 52.6cm. Maintains full-time sine wave output within 2% of selectable 200/208/220/230/240V nominal during brownouts as low 100V and overvoltages as high as 300V. Expandable runtime is supported with optional BP192V12-3U external battery packs. Battery independent restart ensures automatic UPS power-up without user interaction after lengthy power outages, even when batteries are expired and require replacement. Double-conversion operation converts raw input from AC to DC, then re-synthesizes output power back to perfect sine wave AC with enhanced protection from harmonic distortion, fast electrical impulses and other hard-to-solve power problems not addressed by other UPS types. Highly efficient operation in optional economy mode significantly reduces BTU heat output and operating energy costs. Network-grade AC surge and noise suppression. Supports detailed monitoring of equipment load levels, self-test data and utility power conditions via built-in RS-232 and USB interfaces. Optional network management card options available. HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X. PowerAlert monitoring software offers detailed site power and UPS updates with support for safe auto-shutdown of connected systems as UPS batteries become depleted. Supports Emergency Power Off (EPO) via built-in interface. Front panel LEDs and LCD readout with scroll controls support front-panel visual monitoring of all major UPS for a variety of control options to support advanced UPS settings and configurations. LED / LCD display panel rotates for viewing in rackmount or tower configurations. Hardwire input and 4 C19 outlets. Support for optional North American and International cordsets. External battery packs are field replaceable and hot swappable. Tripp Lite SU6000RT4UHVG 6000VA / 6kVA / 5400 watt on-line, double-conversion UPS system in a single 4U rack/tower compatible housing (output is limited to 4992 watts when used at 208V with L6-30P input plug) Full-time active power conditioning maintains clean, continuous dual-conversion AC output free of voltage fluctuations, power interruptions and line noise Fault tolerant electronic bypass maintains utility output during a variety of UPS fault conditions Detachable back panel PDU contains hardwire input line cord connection, output receptacles and manual bypass switch to support hot-swappable whole UPS replacement with no interruption to connected equipment Hardwire input and 4 C19 output receptacles Included rail kit supports 4U 19 inch rackmount installation in 4 post racks Optional 2POSTRMKITHD supports installation in 2 post 19 inch racks (1 required for SU6000RT4UHVG) Optional 2-9USTAND supports upright tower placement (1 required for SU6000RT4UHVG) Maximum installed rack depth of only 20.7 in. / 52.6cm Maintains full-time sine wave output within 2% of selected 200/208/220/230/240V nominal in double conversion mode Corrects brownouts to 156V at full load (100V at 50% load or less) Corrects overvoltages to 290V at full load (300V at 90% load or less) Supports 50/60Hz operation for worldwide frequency compatibility Double-conversion operation offers full-time AC to DC, then DC to AC conversion to maintain perfectly regulated sine wave AC output with enhanced protection from harmonic distortion, fast electrical impulses and other hard-to-solve power problems not addressed by other UPS types High efficiency ECONOMY MODE operation significantly reduces BTU heat output and operating energy costs Network-grade AC surge and noise suppression Supports detailed monitoring of equipment load levels, self-test data and utility power conditions via built-in RS-232, USB and network management card options Compatible with Tripp Lite UPS management card options TLNETCARD, WEBCARDLX, SNMPWEBCARD, MODBUSCARD and RELAYIOCARD Optional WEBCARDLX (sold separately) with the latest version of PowerAlert Device Manager firmware (PADM20) provides enhanced remote management capabilities PADM20 and PowerAlert Element Manager (PAEM) form a powerful tool for expanding maintenance functions in large installations, including firmware update checks and backup and restoration of device configurations Optional RELAYIOMINI interface module offers three configurable hard contact closure outputs for custom event notification (requires removal of USB interface module) HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X USB & Serial ports enable data-saving unattended shutdown when used with Tripp Lite's PowerAlert software, available via FREE download from www.tripplite.com/poweralert Front panel LEDs and LCD readout with scroll controls support front-panel visual monitoring of all major UPS functions with support for a variety of control options to support advanced UPS settings and configurations LED/LCD display panel rotates for viewing in rackmount or tower configurations Supports Emergency Power Off (EPO) via built-in interface Battery independent restart ensures automatic UPS power-up without user interaction after lengthy power outages, even when batteries are expired and require replacement BP192V12-3U external battery packs are field replaceable and hot swappable Intelligent battery management system with temperature-compensated charging extends battery life Some external battery configurations require the use of Tripp Lite's External Battery Configuration Software (see manual) Frequency conversion mode enables conversion of 60Hz to 50Hz or 50Hz to 60Hz (no de-rating)

Specifications

  • Output power capacity
    6 kVA
  • Output power
    5400 W
  • Input operation voltage (min)
    200 V
  • Input operation voltage (max)
    240 V
  • Input frequency
    50/60 Hz
  • Output operation voltage (min)
    208 V
  • Output operation voltage (max)
    240 V
  • Maximum current
    40 A
  • Efficiency
    96%
  • Power factor
    0.9
  • Crest factor
    3:1
  • Emergency Power Off (EPO)
    Y
  • EMI/RFI noise filtering
    Y
  • Noise level
    60 dB
  • Audible alarm(s)
    Y
  • Country of origin
    China
  • AC outlet types
    C19 coupler
  • AC outlets quantity
    4 AC outlet(s)
  • USB 2.0 ports quantity
    1
  • Serial ports quantity
    1
  • RS-232 ports
    1
  • Typical backup time at full load
    2 min
  • Typical backup time at half load
    8.5 min
  • Battery recharge time
    6 h
  • Hot-swap battery
    Y
  • Form factor
    Rackmount
  • Product colour
    Black
  • Rack capacity
    4U
  • Cable length
    3 m
  • Display type
    LED
  • LED indicators
    Y
  • Certification
    UL1778 CSA FCC Part 15 Category A IEC 61000-4-5 1995 B
  • Operating temperature (T-T)
    0 - 40 °C
  • Storage temperature (T-T)
    -15 - 50 °C
  • Operating altitude
    0 - 3000 m
  • Sustainability certificates
    RoHS
  • Width
    445 mm
  • Depth
    526 mm
  • Height
    174 mm
  • Weight
    49 kg
  • Package width
    863.6 mm
  • Package depth
    609.6 mm
  • Package height
    762 mm
  • Package weight
    86.2 kg
  • Master (outer) case width
    863.6 mm
  • Master (outer) case length
    609.6 mm
  • Master (outer) case height
    762 mm
  • Master (outer) case gross weight
    86.2 kg
  • Products per master (outer) case
    1 pc(s)
  • Number of phases
    1
  • Input connection type
    L6-30P
  • Relative humidity
    0 - 95%
  • Management platform
    SNMP
  • Warranty Info
    2-year limited

Reviews

Write Your Own Review
You're reviewing:Tripp Lite SU6000RT4UHVG SmartOnline 208/240, 230V 6kVA 5.4kW Double-Conversion UPS, 4U Rack/Tower, Extended Run, Network Card Options, USB, DB9 Serial, Bypass Switch, C19