Skip to content

Tripp Lite PDUMH32HVATNET 7.7kW Single-Phase Switched Automatic Transfer Switch PDU, Two 200-240V IEC309 32A Blue Inputs, 16-C13 2-C19 Outlets, 2U, TAA

SKU
PDUMH32HVATNET
Your price £1,028.52
Out of stock
7.7kW Single-Phase Switched Automatic Transfer Switch PDU, Two 200-240V IEC309 32A Blue Inputs, 16-C13 2-C19 Outlets, 2U, TAA
View full product details
Sign in or register your company account to unlock exclusive benefits:
 
  • Shop top tech from leading brands
  • Order by 3pm for next day delivery
  • 24/7 account access
Overview

More Information

Highlights

The PDUMH32HVATNET 7.7kW Single-Phase 200-240V Switched Automatic Transfer Switch / ATS PDU provides remote power monitoring and enables redundant power for network devices with non-redundant power supply configurations. Ideal for data centers and server rooms, it mounts in 2U of space in EIA-standard racks and features 18 switched outlets (16 C13 and two C19) in two load banks, each bank protected by a 20A circuit breaker. Dual 3-meter input cords with IEC309 32A Blue (2P+E) plugs connect to separate primary and secondary single-phase 230V power sources. The PDU constantly evaluates the power quality of both input sources. Dynamic solid-state (TRIAC) automatic transfer switching allows the PDU to switch to the secondary source within 1–5 milliseconds should the primary source fail or become unstable to ensure your connected equipment operates without interruption. Built-in LX Platform network management interface. The Java-free LX Platform HTML5-based network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separate) provide a variety of environmental monitoring capabilities. Protocols supported include HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP. Primary and Secondary Inputs for Power Redundancy Provides remote power monitoring and enables redundant power for network devices single-corded and other non-redundant power supply configurations Dual 3m input cords with IEC309 32A Blue (2P+E) plugs connect to separate primary and secondary single-phase power sources Automatic Transfer Switching Dynamic solid-state (TRIAC) automatic transfer switching Switches to secondary power source if primary source fails or becomes unstable 1–5 ms transfer time ensures uninterrupted operation of connected equipment Built-in processor monitors both sources and prevents switching if secondary source is unavailable or of lower quality than primary source Multifunction Digital LED Display Reports source A and source B input power status and other information, including power availability, line voltage, frequency, amps, kilowatts and power factor Advanced LX Platform Interface LX Platform interface allows full remote access for power monitoring with email notifications via secure web browser, SNMP, telnet or SSH Real-time load/current data with billing-grade accuracy (+/- 1 percent) Automated alerts help prevent accidental overloads, power loss and downtime Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities Broad Communications Compatibility Protocols supported include HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP Breaker Protected Output Load Banks Protect each of 2 single-phase output banks Front-panel LED indicates when breaker has tripped Cord Retention Sleeves Set of Plug-lock output power cable retention sleeves prevent accidental disconnection of connected devices Mounts Horizontally in 2U of Rack Space Compatible with EIA-standard 19 in. 4-post racks and rack enclosures TAA-Compliant Compliant with the Federal Trade Agreements Act (TAA) for GSA Schedule purchases

Specifications

  • PDU types
    Switched
  • Rack capacity
    2U
  • Type
    Single-phase
  • Mounting
    Horizontal
  • Housing material
    Metal
  • Product colour
    Black
  • Display
    LCD
  • AC outlets quantity
    18 AC outlet(s)
  • AC outlet types
    C13 coupler, C19 coupler
  • Power plug
    IEC309
  • Ethernet LAN (RJ-45) ports
    1
  • LED indicators
    Y
  • Cable length
    3 m
  • Supported network protocols
    HTTP, HTTPS, PowerAlert®, SMTP, SNMPv1, SNMPv2, SNMPv3, Telnet, SSH, FTP, DHCP, BOOTP, NTP
  • Nominal input voltage
    200-240 V
  • Maximum current
    32 A
  • AC input frequency
    50 - 60 Hz
  • Nominal output voltage
    200-240 V
  • Maximum power
    7700 W
  • Width
    444.5 mm
  • Depth
    317.5 mm
  • Dimensions (WxDxH)
    444 x 317 x 88 mm
  • Height
    88.9 mm
  • Weight
    6.21 kg
  • Package dimensions (WxDxH)
    424 x 505 x 198 mm
  • Package weight
    9.12 kg
  • Package width
    457.2 mm
  • Package depth
    497.8 mm
  • Package height
    198.1 mm
  • Manual
    Y
  • Storage temperature (T-T)
    -15 - 50 °C
  • Operating relative humidity (H-H)
    5 - 95%
  • Sustainability certificates
    RoHS
  • Country of origin
    Taiwan
  • Products per master (outer) case
    1 pc(s)
  • Warranty Info
    2-year limited

Reviews

Write Your Own Review
You're reviewing:Tripp Lite PDUMH32HVATNET 7.7kW Single-Phase Switched Automatic Transfer Switch PDU, Two 200-240V IEC309 32A Blue Inputs, 16-C13 2-C19 Outlets, 2U, TAA