Highlights
Problem Description ASA 5500-X security appliances that shipped from March 16, 2012 through June 11, 2012 contain the incorrect factory default configuration. This requires the user to follow special procedures for system initialization. Background The ASA 5500-X appliances shipped from March 16, 2012 through June 11, 2012 were not loaded with the correct factory default configuration and must be initialized using special commands. The procedures contained in the Quick Start Guide are insufficient to properly initialize the affected units. Problem Symptoms Users attempting to initialize the affected ASA 5500-X appliances using the Quick Start Guide will observe that the management 0/0 ports are in the down/down condition. In addition, ASDM for on box management is not accessible. Workaround/Solution The factory default configuration can be applied using the following command: config factory-default Note that the ASA 5515-X appliance does not support the command above due to Cisco bug ID CSCtz73669. The unit must be restored to the factory default configuration using the command series shown below.Specifications
-
Firewall throughput
2000 Mbit/s
-
Maximum data transfer rate
4000 Mbit/s
-
VPN throughput
700 Mbit/s
-
IPS/IDS throughput
1300 Mbit/s
-
Mobile VPN IPSec
5000
-
Mobile VPN SSL
2
-
Maximum firewall connections per second
50000
-
Heat dissipation
458 BTU/h
-
Concurrent connections
1000000
-
Noise level
67.9 dB
-
Number of VLANs
500
-
Security algorithms
3DES
-
VPN support
3DES/AES
-
Connectivity technology
Wired
-
Gigabit Ethernet (copper) ports quantity
6
-
USB 2.0 ports quantity
2
-
Serial ports quantity
1
-
Internal memory
16384 MB
-
Storage media type
SSD
-
RAID levels
1
-
Number of HDDs installed
1
-
Total storage capacity
120 GB
-
SSD capacity
120 GB
-
RAID support
Y
-
Rack mounting
Y
-
Form factor
1U
-
AC input voltage
100-240 V
-
AC input frequency
50 - 60 Hz
-
Input current
15 A
-
Power consumption (typical)
90 W
-
Peak power
134 W
-
Redundant power supply (RPS) support
Y
-
Number of power supply units
1
-
Harmonized System (HS) code
85176990
-
Minimum flash memory
8192 MB
-
Operating temperature (T-T)
-5 - 40 °C
-
Storage temperature (T-T)
-25 - 70 °C
-
Operating relative humidity (H-H)
10 - 90%
-
Storage relative humidity (H-H)
10 - 90%
-
Operating altitude
0 - 3050 m
-
Non-operating altitude
0 - 4572 m
-
Dimensions (WxDxH)
429 x 484 x 42.4 mm
-
Weight
7.63 kg